Chapter 3 Troubleshooting
004-340 IOT RAM FAILURE
Description
The result was NG at the MCU PWB RAM TEST.
BSD on : CH3.1A CH3.6A
Procedure
Check the wire between the MCU PWB and the MCU NVM
PWB if the problem persists after turning the power On/Off.
Replace the MCU PWB if the problem persists after
checking.(PL13.1)
If the problem persists after replacing the MCU PWB, replace
the MCU MF NVM PWB.(PL13.1)
004-341 IOT LOGIC FAILURE
Description
Operation failure of the MCU PWB. Or, poor
contact of the +5 VDC Interlock
BSD on : CH3.1A CH3.6A
Procedure
• Perform re-installation of the software.
• Check the connectivity of the J410 if the problem persists
after white paper is output.
Is +5 VDC measured at the J401-B20?
Y
N
Is +5 VDC measured at the J568-5?
Y
N
Is +5 VDC measured at the J568-1?
Y
N
Check the wire between the J568-2 and FS134
for an open circuit or poor contact.
Replace the LSU (ROS) Assy.(PL3.1)
Check the wire between the J568-5 and P400-9 for an open
circuit or poor contact.
Replace the MCU PWB. (PL13.1)
If the problem persists, replace the LSU (ROS) Assy.(PL3.1)
004-342 IOT FLASH ROM LIMIT FAILURE
Description
Operation failure of the FLASH ROM.
BSD on : CH3.1A CH3.6A
Procedure
If the problem persists after turning the power On/Off, replace
the MCU PWB.(PL13.1)
004-343 IOT FLASH ROM R/W FAILURE
Description
Operation failure of the FLASH ROM.
BSD on : CH3.1A CH3.6A
Procedure
If the problem persists after turning the power On/Off, replace
the MCU PWB.(PL13.1)
004-344 IOT MICRO PITCH FAILURE
Description
The MICRO PIT did not occur within the
specified time.
BSD on : CH3.1A CH3.6A
Procedure
If the problem persists after turning the power On/Off, replace
the MCU PWB.(PL13.1)
004-345 IOT HVPS COMMUNICATION FAILURE
Description
Communication error between the MCU PWB
and the HVPS CONTROL PWB.
BSD on : CH3.1D CH3.6A
Procedure
Is +5 VDC measured between the MCU PWB J406-B5 (+) and
GND (-)?
Y
N
Replace the MCU PWB. (PL13.1)
Turn Off the power. Check conductivity of the following:
Between the HVPS CONTROL PWB J574-7 and the MCU
PWB J406-B3
Between the HVPS CONTROL PWB J574-6 and the MCU
PWB J406-B4
Is the resistance 1 Ohm or less for both wires?
Y
N
Repair the open circuit or poor contact.
Is the resistance between the HVPS CONTROL PWB J574-9
and the MCU PWB J406-B1 1 Ohm or less?
Y
N
Repair the open circuit or poor contact.
If the problem persists after replacing the MCU PWB (PL13.1),
replace the HVPS CONTROL PWB.(PL9.1)
Содержание DP-C321
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......