3-90
Chapter 3 Troubleshooting
015-381 Platen AGC CH2 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH2 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-382 Platen AGC CH3 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH3 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-383 Platen AGC CH4 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH4 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-384 Platen AGC CH5 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH5 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-385 Platen AGC CH6 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH6 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-386 Platen AOC CH1 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AGC CH1 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-387 Platen AOC CH2 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AOC CH2 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
If the problem persists, replace the following
components in sequence:
• IIT/IPS PWB (PL16.3)
• CCD Flat Cable (PL16.4)
• CCD PWB (PL16.4)
015-388 Platen AOC CH3 Failure
BSD on : CH6.12A
[Detection Conditions
] Platen AOC CH3 Failure
[Actions]
Turn the power On/Off.
If the problem persists after turning the power On/Off,
check the connection of the IPS PWB P721 and CCD
Connector D741.
Содержание DP-C321
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......