2-4
Chapter 2 Maintenance
Adjustment
Procedure
1.
Enter
DC921
.
2.
Select the replaced sensor color from "Sensor Colors" and check it in the TC/ATC Sensor
Setup screen.
3.
Write down the last 2 digits of the 3-digit number attached to the replaced sensor, obtain
[Sensitivity Slant Initial Value] and [Standard TC Output Initial Value] in the following
Comparison table, and input each value on the screen.
4.
Click [Execute].
5.
Continue to execute ADJ1. 1. 3 TRC control (Tone Up/Down).
Sensor Sensitivity Comparison Table
Bar Code No.
(Last 2-digit)
Sensitivity Slant Initial Value
Standard TC Output Initial
Value
00
526
169
01
572
166
02
617
162
03
663
158
04
708
154
05
753
150
06
799
146
07
844
142
08
889
138
09
934
134
10
526
171
11
572
168
12
617
164
13
663
160
14
708
156
15
753
152
16
799
148
17
844
144
18
889
140
19
934
136
20
527
174
21
572
169
22
617
166
23
663
162
Содержание DP-C321
Страница 4: ...This page is intentionally left blank ...
Страница 5: ...Chapter 1 General ...
Страница 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Страница 23: ...1 17 Chapter 1 General ...
Страница 24: ...Chapter 2 Maintenance ...
Страница 63: ...Chapter 3 Troubleshooting ...
Страница 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Страница 378: ...3 304 Chapter 3 Troubleshooting Read Write Read Write Description Memory Spool 512 KB 32 MB 256 KB interval ...
Страница 445: ...Chapter 4 Parts List ...
Страница 527: ...4 80 Chapter 4 Parts List 17 RACK PL17 1 Rack Ref No Part No Description 7901 17E9471X Rack Caster Front j0mf51901 ...
Страница 548: ......