3-145
Chapter 3 Troubleshooting
3. 4. 4. 11 DC355 Hard Disk Diag Program (Sub System)
Function Replace the Hard Disk (HDD), and perform Setup Replacement Judgement, etc at
checking.
Procedure
1. Select the "Sub System" tab on the Service Mode screen.
2. Select [
DC355
] on the Sub System screen.
3. The "Hard Disk Diag Program" screen is displayed.
4. Select [Target Hard Disk].
5. Select the appropriate function.
• Setup
• Hard Disk Test
• Diagnostic
• Trouble Forecast
6. Select [Execute].
For detailed procedure and explanation, refer to Chapter 2 ADJ1.1.8 DC355 Hard Disk
Diag Program.
MP.All (Multiple Purpose) means to execute the selected functions to each partition in
the order of partition 1 to 6.