![Panasonic CS-RZ25TKR Скачать руководство пользователя страница 62](http://html2.mh-extra.com/html/panasonic/cs-rz25tkr/cs-rz25tkr_service-manual_3472471062.webp)
62
12.2.4.1 Wire Stripping and Connecting Requirement
12.2.5 Cutting and Flaring the Piping
1 Please cut using pipe cutter and then remove the burrs.
2 Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused.
Turn the piping end down to avoid the metal powder entering the pipe.
3 Please make flare after inserting the flare nut onto the copper pipes.
WARNING
RISK OF FIRE
JOINING OF WIRES
MAY CAUSE
OVERHEATING
AND FIRE.
OR
Use complete
wire without joining.
Use approved
socket and plug
with earth pin.
Wire connection
in this area must
follow to national
wiring rules.
OR
OR
Do not joint wires
Wire stripping
No loose strand
when inserted
10 ± 1 mm
5 mm or more
Indoor/outdoor connection
terminal board
(gap between wires)
Conductor
fully inserted
Conductor
over inserted
Conductor not
fully inserted
ACCEPT
PROHIBITED
PROHIBITED
1. To cut
When properly flared, the internal surface of the
fl are will evenly shine and be of even thickness.
Since the flare part comes into contact with the
connections, carefully check the flare finish.
Improper fl aring
Inclined Surface
damaged
Cracked Uneven
thickness
3. To fl are
Bar
Red arrow mark
Handle
Core
Yoke
Clamp handle
Bar
0 – 0.5 mm
Copper
pipe
Reamer
2. To remove burrs
Point down
Pipe