![Panasonic CS-RZ25TKR Скачать руководство пользователя страница 111](http://html2.mh-extra.com/html/panasonic/cs-rz25tkr/cs-rz25tkr_service-manual_3472471111.webp)
111
17. Troubleshooting
Guide
17.1 Refrigeration Cycle System
In order to diagnose malfunctions, make sure that there are no
electrical problems before inspecting the refrigeration cycle.
Such problems include insufficient insulation, problem with the
power source, malfunction of a compressor and a fan.
The normal outlet air temperature and pressure of the refrigeration
cycle depends on various conditions, the standard values for them
are shown in the table on the right.
Value of electric
current during operation
Difference in the intake
and outlet
air temperatures
Lower than specified
Higher than specified
Cooling Mode
Heating Mode
High
Low
Low
Low
Low
Low
Gas side
pressure
Dusty condenser
preventing heat radiation
●
Measuring electric current
during
operation
●
Measuring gas side pressure
Excessive amount
of refrigerant
Inefficient compressor
Insufficient refrigerant
Insufficient refrigerant
Inefficient compressor
Clogged strainer or
expansion valve
Clogged strainer, expansion
valve or capillary tube
Less than 8°C at the cooling mode.
Less than 14°C at the cooling mode.
More than 8°C
(15 minutes after an
operation is started.)
at cooling mode.
Above 14°C
(15 minutes after an
operation is started.)
at heating mode
Normal
●
Measuring the air temperature
difference
Normal Pressure and Outlet Air Temperature (Standard)
Gas pressure
MPa
(kg/cm
2
G)
Outlet air
temperature
(°C)
Cooling Mode
0.9 ~ 1.2 (9 ~ 12)
13 ~ 17
Heating Mode 2.0 ~ 2.7 (20 ~ 27)
32 ~ 42
*Condition: • Indoor fan speed = High
• Outdoor temperature 35°C at the cooling
mode and 7°C at the heating mode
• Compressor operates at rated frequency