55
14.4.12 H58 (Patrol Sensor Abnormality)
Malfunction Decision Conditions
•
If Patrol sensor feedback is 0V or 5V continuous for 6 hours.
•
Error will display only when the Patrol operation is ON.
Malfunction Caused
•
Faulty
connector
connection.
•
Faulty Patrol sensor.
Troubleshooting
NO
When abnormality indication starts again
•
Defective
Patrol
sensor.
•
Replace the Patrol sensor.
Has the error occurred after 6 hours continuous of
PATROL ON function?
Check at indoor PCB’s CN-DISP (14-15) and CN-DISP1 (1-2)
connector. No loose cable or broken?
•
Correct loose or broken cable /
connector.
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...