24
Piping direction
Right
Right
Rear
Right bottom Left
Rear
Left bottom
Left
(Front side)
Attention not to bend
up drain hose
Insulation of piping connections
• Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to
the wall
Remote control holder
Remote
control
Remote
control
holder
* Vinyl Tape
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Installation parts you
should purchase (*)
Installation plate
Brushing-Sleeve (*)
Sleeve (*)
Putty (*) (Gum type Sealer)
Bend the pipe as closely on the wall as possible,
but be careful that it doesn’t break.
Power (*) supply cable
Vinyl tape (wide) (*)
• Apply after carrying out a drainage test.
• To carry out the drainage test, remove the air
filters and pour water into the heat exchanger
Saddle (*)
Connecting cable
Liquid side piping (*)
Gas side piping (*)
Additional drain hose
300
mm
or m
ore
100
m
m
or m
ore
10
0
m
m
or
m
or
e
10
00
m
m
or
m
or
e
50mm
or more
65
m
m
or
m
ore
It is advisible to avoid more than 2 blockage directions.
10. Installation
Instruction
10.1 Select The Best Location
10.1.1 Indoor
Unit
•
Do not install the unit in excessive oil fume area such as kitchen, workshop and etc.
•
There should not be any heat source or steam near the unit.
•
There should not be any obstacles blocking the air circulation.
•
A place where air circulation in the room is good.
•
A place where drainage can be easily done.
•
A place where noise prevention is taken into consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
•
Recommended installation height for indoor unit shall be at least 2.5m.
10.1.2 Outdoor
Unit
•
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
•
There should not be any animal or plant which could be affected by hot air discharged.
•
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
•
Do not place any obstacles which may cause a short circuit of the discharged air.
•
If piping length is over the rated length, additional refrigerant should be added as shown in the table below:
10.1.3 Indoor/Outdoor Unit Installation Diagram
Piping size
Model Horse
Power
Gas Liquid
Rated Length
(m)
Max Elevation
(m)
Min Piping
Length (m)
Max Piping
Length (m)
Additional
Refrigerant
(g/m)
Piping length
for add. gas
(m)
PS9*** 3/8”
1/4"
7.5
5
3
15
15
7.5
PS12***
1.0 ~
1.75HP
1/2" 1/4" 7.5
5
3
15
15
7.5
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...