14.4.17 F91 (Refrigeration Cycle Abnormality)
Malfunction Decision Conditions
•
During cooling, compressor frequency = Fcmax.
•
During cooling and heating operation, running current: 0.65A < I < 1.65A.
•
During cooling, indoor intake - indoor pipe < 4°C
Malfunction Caused
•
Refrigerant shortage (refrigerant leakage)
•
Poor compression performance of compressor.
•
2/3 way valve closed.
•
Detection error due to faulty indoor intake air or indoor pipe temperature sensors.
Troubleshooting
2/3-way valve opened?
Oil oozing out from the 2/3 way valve?
•
Replace the capillary tube or dryer.
When F91 indication happens
For safety reason and to prevent component
breakdown, always switch off the power
before remove and connect the component.
Check the indoor air intake and pipe
temperature sensors.
•
Open 2/3 way valve
Check for gas leaking.
•
Repair the pipe flare or union nuts.
Reclaim and recharge refrigerant.
NO
NO
YES
YES
Does it conform to the sensor
characteristic chart?
•
Replace the indoor intake air or pipe
temperature sensor
NO
Capillary tube or dryer clogged?
Charge for a specified amount of fresh
refrigerant.
YES
Refrigerant cycle abnormality error again?
•
Replace outdoor unit PCB &
compressor
NO
YES
•
Procedure
complete
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...