27
Rear view for left piping installation
Drain cap
Drain hose
Replace the drain hose
Adjust the piping slightly downwards.
Drain hose
Connecting
cable
How to pull the piping and drain hose out, in
case of the embedded piping
PVC tube
for drain
hose
Indoor unit
72 mm
Piping
Cable
Apply putty or
caulking material
to seal the wall
opening.
Connecting
cable
Piping
More
than
470 m
m
Mo
re t
han
115
0 m
m
PVC tube (VP-65) for piping
and connecting cable
PVC tube for drain hose (VP-30)
PVC tube for
drain hose (VP-20)
M
or
e
than
70
0 m
m
In case of left piping how to insert
the connecting cable and drain
hose.
Cable
45
°
Drain
hose
Piping
Drain hose
from main unit
(For the right piping, follow the
same procedure)
Sleeve for piping hole
Drain hose
Piping
Connectin g
cable
More than
1150 mm
10.2.3.3 For the embedded piping
(This can be used for left rear piping & left bottom piping also.)
Replace the drain hose
Bend the embedded piping
Install the Indoor Unit
Cut and flare the embedded piping
Pull the connecting cable into indoor unit
Connect the piping
Insulate and finish the piping
Secure the Indoor Unit
•
Use a spring bender or equivalent to bend the
piping so that the piping is not crushed.
•
When determining the dimensions of the piping, slide the
unit all the way to the left on the installation plate.
•
Refer to the section “Cutting and flaring the piping”.
•
The inside and outside connecting cable can be
connected without removing the front grille.
•
Please refer to “Connecting the piping” column in the
outdoor unit section (Below steps are done after connecting
the outdoor piping and gas-leakage confirmation
•
Please refer to “Piping and finishing” column in the outdoor
section and “Insulation of piping connections” column as
mentioned in Indoor/Outdoor unit installation.
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...