28
10.2.4 Connect the Cable to the Indoor Unit
The power supply cable and indoor unit and outdoor unit connecting cable can be connected without removing the
front grille.
1 Install the indoor unit on the installation holder that mounted on the wall.
2 Open the front panel and grille door by loosening the screw.
3 Connecting
the
power supply cable
according to position.
Cable connection to the power supply through Isolating Devices (Disconnecting means).
o
Connect the approved polychloroprene sheathed power supply cable 3 x 15 mm
2
(1.0~ 1.75HP) or 3 x
2.5 mm
2
(2.0 ~ 2.5HP), type designation 245 IEC 57 or heavier cord to the terminal board, and connect
the others end of the cable to Isolating Devices (Disconnecting means).
4 Secure the power supply cable into the control board with the holder (clamper).
5 Connect indoor unit and outdoor unit cable according to the position.
Connection cable
between indoor unit
and outdoor unit shall be approved polychloroprene sheathed 4 x 1.5 mm
2
(11.HP ~ 1.75HP) or 4 x 2.5 mm
2
(2.0 ~ 2.5HP) flexible cord, type designation 245 IEC 57 or heavier cord.
6 Secure the indoor and outdoor cable connection onto the control board with the holder.
7 Close grille door by tighten with screw and close the front panel.
•
This unit must be properly earthed.
•
Ensure the color of wires of outdoor unit and the terminal numbers are the same to the indoor’s respectively.
•
Earthed lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety in case
of the slipping out of the cord from the anchorage.
•
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0mm contact gap.
•
Secure the cable onto the control board with the holder (clamper).
10.2.4.1 Wiring Stripping and connecting requirement
Wire stripping
5 mm
or more
(gap between
wires)
ACCEPT
PROHIBITED
Conductor
over insert
No loose strand when insert
Indoor/outdoor
connecting
terminal board
10
±
1
m
m
Conductor
fully insert
PROHIBITED
Conductor not
fully insert
Terminals on the outdoor unit
1
2
3
Colour of wires
Terminals on the indoor unit
L
N
1
2
3
Terminals on the isolating devices
(L) (N)
(Disconnecting means)
L
N
1
2
3
3
5
Terminal
Board
Earth wire
longer than
other AC
wires for
safety
reason
Control
Board
Earth wire
longer than
other AC
wires for
safety
reason
Holder
Holder
Indoor & outdoor
cable connection
Powe r
supply cable
Isolating Device s
Outdoor unit
4
6
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...