26
Cover for the
bottom piping
Cover for the
bottom piping
Tapeit with
piping in a position as
mentioned in
Fig. below
Cover for
the right
piping
Piping
Drain
hose
Cover
for the
left
piping
Cover for piping
Right Rear piping
In case of the cover is cut,
keep the cover at the rear of
chassis as shown in the
illustration for future
reinstallation.
(Left, right and 2 bottom
covers for piping.)
How to keep the cover
Right and Right Bottom piping
Cover for the
bottom piping
Tapeit with piping in a
position as mentionedin
Fig. below
Cover for
the right
piping
Piping
Drain hose
Coverfor
the left
piping
Install the indoor unit
Hook the indoor unit onto
the upper portion of
installation plate. (Engage
the indoor unit with the
upper edge of the
installation plate). Ensure
the hooks are properly
seated on the installation
plate by moving it in left
and right.
Drain hose
Sleevefor
piping hole
Indoor unit
Hooksat
installation
plate
Piping
Installation
plate
Secure the Indoor Unit
Press the lower left and right
side of the unit against the
installation plate until hooks
engages with their slot (sound
click).
Unit’s
hook
Insert the connecting cable
To take out the unit, push the
marking at the
bottom unit, and pull it slightly towards you to
disengage the hooks from the unit.
Guide
surface
Connecting cable
Ab
out
7–
8 c
m
Connecting
cable
Gas side
piping
Liquid side
piping
Drain hose
This can be used for left rear piping and bottom piping also.
Marking
10.2.3 Indoor Unit Installation
!
Piping
Piping
Intake grille
Shock absorber
• Use shock absorber during pull out
the piping to protect the intake grille
from damage.
Do not turn over the unit without it ’s shock
absorber during pull out the piping. It may
cause intake grille damage
Caution
!
10.2.3.1
For the right rear piping
10.2.3.2
For the right and right bottom piping
Pull out the Indoor Piping
Install the Indoor Unit
Secure the Indoor Unit
Insert the power supply cable and connecting cable
Insert the cables from bottom of the unit through
the control board hole until terminal board area.
Pull out the Indoor Piping
Install the Indoor Unit
Insert the power supply cable and connecting cable
Secure the indoor unit
Insert the cables from bottom of the unit through
the control board hole until terminal board area.
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...