66
14.4.23 F99 (Output Over Current Detection)
Malfunction Decision Conditions
During operation of cooling and heating, when an output over-current (18.5A) is detected by checking the current that
flows in the inverter DC peak sensing circuitry.
Malfunction Caused
•
DC peak due to compressor failure.
•
DC peak due to defective power transistor(s).
•
DC peak due to defective outdoor unit PCB.
Troubleshooting
•
Checking the power transistor
•
Never touch any live parts for at least 10 minutes after turning off the circuit breaker.
•
If unavoidable necessary to touch a live part, make sure the power transistor’s supply voltage is below 50V using
the tester.
•
For the UVW, make measurement at the Faston terminal on the board of the relay connector.
Tester’s negative terminal
Power transistor (+)
UVW
Power transistor (-)
UVW
Tester’s positive terminal
UVW
Power transistor (+)
UVW
Power transistor (-)
Normal resistance
Several k
Ω
to several M
Ω
Abnormal resistance
0 or
∞
Check the compressor winding resistance:
•
Turn off the power and disconnect
the harness U, V and W
•
Measure the winding resistance
between U-V, V-W and W-U.
When F99 indication happens
For safety reason and to prevent component
breakdown, always switch off the power
before remove and connect the component.
Get restarted and measure the input
current.
NO
Input current > 18.5A?
•
Replace the outdoor unit PCB.
NO
YES
Are the compressor’s winding resistance
(U-V, V-W or U-W) shorted?
•
Compressor defective due to winding
shorted.
•
Replace
compressor
•
Outdoor electronic circuit defect due
to power transistor short
•
Replace the outdoor unit PCB.
YES
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...
Страница 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Страница 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Страница 18: ...18 8 2 2 CU PS12JKT...
Страница 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Страница 22: ...22...
Страница 23: ...23 9 3 2 CU PS12JKT...