![Panasonic CS-PS9JKT Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/panasonic/cs-ps9jkt/cs-ps9jkt_service-manual_4707702025.webp)
25
B
4
3
6
5
C
A
128
Wall
Wall
More than 1
Wall
than 2
More than 1
Screw
More
Indoor unit
Installation
plate
Measuring
Tape
241.5mm
128mm
234.5mm
128mm
Wall
Indoor
Outdoor
15 mm
Sleeve for
tube ass’y
Approx. 5 - 7 mm
Bushing for tube ass’y
Putty or caulking compound
Ø 70 through hole
10.2 Indoor Unit
10.2.1 How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent if from the vibration.
Dimension
Model
○
1
○
2
○
3
○
4
○
5
○
6
PS9***,
PS12***
485mm 82mm 165mm 158mm 93mm 145mm
The centre of installation plate should be at more than
○
1 mm at right and left of the wall.
The distance from installation plate edge to ceiling should more than
○
2 .
From installation plate left edge to unit’s left side is
○
3 .
From installation plate right edge to unit’s right side is
○
4 .
○
B
: For left side piping, piping connection for liquid should be about
○
5 from this line.
: For left side piping, piping connection for gas should be about
○
6 from this line.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the wall, consider using anchor bolts.)
o
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø70mm hole-core drill.
o
Putting measuring tape at position as shown in the diagram above. The hole center is obtained by
measuring the distance namely 128mm for left and right hole respectively. Another method is
intersection point of arrow mark extension.
o
Drill the piping plate hole at either the right or left and the hole should be slightly slanted to the outdoor
side.
10.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1 Insert the piping sleeve to the hole.
2 Fix the busing to the sleeve.
3 Cut the sleeve until it extrudes about 15mm from the wall
4 Finish by sealing the sleeve with putty or caulking compound at the
final stage.
Caution
When the wall is hollow, please be sure to use the sleeve for tube
ass’y to prevent dangers caused by mice biting the connecting
cable.
Содержание CS-PS9JKT
Страница 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 8: ...8 4 Dimensions 4 1 Indoor Unit...
Страница 10: ...10 5 Refrigeration Cycle Diagram...
Страница 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Страница 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Страница 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Страница 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Страница 15: ...15 7 2 2 CU PS12JKT...