15.4.22 F17 (Indoor Standby Units Freezing Abnormality)
Malfunction Decision Conditions
•
When the different between indoor intake air temperature and indoor pipe temperature is above 10°C or indoor
pipe temperature is below -1.0°C.
Remark:
When the indoor standby unit is freezing, the outdoor unit transfers F17 error code to the corresponding indoor
unit and H39 to other indoor unit(s).
Malfunction Caused
•
Wrong wiring connection
•
Faulty
sensor
•
Faulty expansion valve
Troubleshooting