z
IPv6 network
Manual
Enable or disable manual configuration of the IPv6 address.
Setting value:
On
Enter the IPv6 address manually.
Off
Disable manual entry of the IPv6 address.
Factory settings:
Off
IP address (IPv6)
When [Manual] is set to [On], the IPv6 address must be entered
manually.
Be sure to enter an address unique from other devices.
<NOTE>
• When connecting to the manually specified IP address through a
router, use an IPv6-compatible router, and enable the automatic
configuration function for the IPv6 address. Be sure to configure
an IPv6 address that includes the prefix information provided
by the IPv6-compatible router. For details, refer to the operating
instructions for the router.
Default gateway
When [Manual] is set to [On] for [IPv6 network], enter the default
gateway for the unit’s IPv6 network.
Factory settings:
blank
DHCPv6
Enable or disable use of the IPv6 DHCP function.
Configure the DHCP server so that the same IP address is not
configured for a personal computer that does not use the DHCP
function and other network cameras. For details on server settings,
consult your network administrator.
Setting value:
On
Use the IPv6 DHCP function.
Off
Do not use the IPv6 DHCP function.
Factory settings:
Off
Primary DNS server address
Secondary DNS server address
Enter the IPv6 address of the DNS server.
For details on the IPv6 address of the DNS server, consult your
system administrator.
z
Common (to IPv6/IPv4)
HTTP port
Port numbers are allocated separately.
Setting range:
1 to 65535
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161, 162, 443, 554, 995,
10669, 10670, 59000 to 61000
Factory settings:
80
Line speed
Select one of the following data line speeds. Normally, it is
recommended that the [Auto] default setting be used.
Setting value:
Auto
The line speed is set automatically.
100 M-Full
100 Mbps full duplex
100 M-Half
100 Mbps half duplex
10 M-Full
10 Mbps full duplex
10 M-Half
10 Mbps half duplex
Factory settings:
Auto
Max RTP packet size
Specify whether to limit the size of RTP packets sent from the camera
when using RTP to view camera images.
Setting value:
Unlimited (1500byte)
Unlimited (1500 byte)
Limited (1280byte)
Limited (1280 byte)
Factory settings:
Unlimited (1500byte)
Normally, it is recommended that the [Unlimited(1500byte)] setting be
used.
Select [Limited(1280byte)] when the packet size of the used
communication line is limited. For details on the maximum packet size
of communication lines, consult your network administrator.
HTTP max segment size (MSS)
Select whether to limit the maximum segment size (MSS) transmitted
by a camera when viewing camera images using HTTP.
Setting value:
Unlimited (1460byte)
Unlimited (1460 byte)
Limited (1280byte)
Limited (1280 byte)
Limited (1024byte)
Limited (1024 byte)
Factory settings:
Unlimited (1460byte)
Normally, it is recommended that the default setting be used.
Select [Limited(1024byte)] / [Limited(1280byte] when the maximum
segment size (MSS) of the used communication line is limited. For
details on the maximum segment size (MSS) of communication lines,
consult your network administrator.
Bandwidth control (bitrate)
Select the amount of data to be distributed.
Setting value:
Unlimited / 64kbps / 128kbps / 256kbps / 384kbps / 512kbps /
768kbps / 1024kbps / 2048kbps / 4096kbps / 8192kbps
Factory settings:
Unlimited
<NOTE>
• Set [Audio Mode] to [Off] when selecting [64kbps]. (→page 57, page 76)
• When [Bandwidth control (bitrate)] is set to a low value, the
SnapShot button may not work depending on the use environment.
In such a case, select [JPEG] with the [Compression] button in the
Live screen [Live] and execute SnapShot when distributing images
in the smallest resolution.