HTTPS port
This sets the Port No. to be used with HTTPS.
Port Nos. that can be selected:
1 to 65535
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 554, 995,
10669, 10670, 59000 to 61000
Factory settings:
443
<NOTE>
• This unit will restart if the connection method is changed.
• When using a self-signed certificate:
A warning screen is displayed when accessing the camera by
HTTPS for the first time. Install the self-signed certificate (security
certificate) in your personal computer in accordance with the screen
instructions. (→ page 99)
• When using a server certificate:
Install the Certificate Authority (CA) root certificate or intermediate
certificate in your web browser in advance.
Follow the Certificate Authority (CA) procedures to acquire and
install root certificates and intermediate certificates.
• When accessing the camera by HTTPS, the image display speed
and frame rate of the moving image may reduce.
• When accessing the camera by HTTPS, it may take some time for
the images to be displayed.
• When accessing the camera by HTTPS, images may be disturbed
and sound may be interrupted.
• The maximum number of cameras that can be connected
simultaneously depends on the maximum image size and
distribution format.
z
SNMP
This performs settings relating to the SNMP function. The status of
the unit can be confirmed by connecting to it with SNMP manager. To
use the SNMP function, consult your network administrator.
Community
Input the name of the community to be monitored.
Maximum number
of characters
0 to 32 half-size characters
Invalid characters
Full size characters
Factory settings:
blank
<NOTE>
• Be sure to enter the community name when using the SNMP
function. The SNMP function cannot be used if the community name
field is left blank.
System name
Input the name of the system to control the unit with the SNMP
function.
Maximum number
of characters
0 to 32 half-size characters
Invalid characters
Full size characters
Factory settings:
blank
Location
Input the location where the unit has been installed.
Maximum number
of characters
0 to 32 half-size characters
Factory settings:
blank
Contact
Input the email address or telephone number of the administrator.
Maximum number
of characters
0 to 255 half-size characters
Invalid characters
Full size characters
Factory settings:
blank
z
Diffserv
This performs settings relating to the Diffserv function. The Diffserv
function sets the priority of image/audio data transmitted from the
router.
Priorities set to this unit must be aligned with DSCP values set to the
router.
To use the Diffserv function, consult your network administrator.
DSCP(0-63)
Input the packet priority.
Maximum number
of characters
0 to 63 half-size characters
Factory settings:
0
94
Web screen configurations (continued)
95