– 88 –
Chapter 5 Basic Operations — Memory
[Play Cancel]
Forcibly terminates the macro being played back.
3
Select an item in the [Work Status] column.
[Current Event]
Displays the number of current events in the work memory.
[Total Event]
Displays the total number of events in the work memory.
[Used]
Displays the usage of the work memory.
[Remain]
Displays the remaining capacity of the work memory.
Registering in the work memory
Register a macro in the work memory.
1
Select the <MEM> button
→
[MACRO]
→
[Macro] tab.
2
Select [New] in the [Edit] column to initialize the work memory.
f
When this operation is performed, the timeline currently in the work memory is deleted. If it is required, register the macro memory in the register
memory.
3
Select [Rec] in the [Rec] column to enter the registration mode.
f
Execute the operation to be registered using the unit.
f
Operations in the multi-selection panel area are outside the scope of macro.
f
When a series of operations are performed with the fader lever or positioner, the last setting value is stored.
f
When [Undo] is selected in the [Rec] column, the latest event being recorded is canceled, reducing the number shown in [Current Event] by one.
This operation can undo events up to the first event. It cannot undo actual operations.
4
Select [Insert Delay] in the [Edit] column.
f
The standby time can be set with [Delay Time] in the [Edit] column.
5
When the registration is complete, select [Stop] in the [Rec] column.
f
The register mode ends.
f
After registration, always save the register memory.
f
Playing back by the menu operation
The macro memory registered in the work memory can be played back to check.
1
Select the <MEM> button
→
[MACRO]
→
[Macro] tab.
2
Select [Play] in the [Play] column.
f
The macro memory in the work memory is played back.
3
Select [Stop] in the [Play] column.
f
The macro memory in the work memory is suspended.
Registering the macro register memory
Register the macro memory created on the work memory in the register memory.
1
Select the <MEM> button
→
[MACRO]
→
[Register] tab.
2
Select [Store] in the [Register] column.
f
The [Store] screen is displayed.
[ME1], [ME2], [DSK], [AUX],
[CLIP], [XPT], [Other]
Select the registration target.
[View]
Fixed to icon display.
[Page]
Switches pages.
[Cancel]
Closes the [Store] screen without registering the target.
[OK]
Closes the [Store] screen after registering the target.
@
@
NOTE
t
A registered register memory can be overwritten.
t
A protected register memory cannot be overwritten. On the [Misc] screen, set [Protect] to [Off].
Recalling the macro register memory (playback)
Recall the macro memory to the work memory from a registered register memory.
1
Select the <MEM> button
→
[MACRO]
→
[Register] tab.
2
Select [Recall] in the [Register] column.
f
The [Recall] screen is displayed.
Содержание AV-HS6000
Страница 5: ...Please read this chapter and check the accessories before use Chapter 1 Overview ...
Страница 29: ...This chapter describes basic operations and matters to be performed prior to use Chapter 4 Preparations ...
Страница 45: ...This chapter describes menu operations Chapter 5 Basic Operations ...
Страница 105: ...This chapter describes the input output signal settings Chapter 6 Input Output Signal Settings ...
Страница 116: ...This chapter describes how to operate the CONFIG menu displayed when the CONF button is pressed Chapter 7 CONFIG Menu ...
Страница 125: ...This chapter describes how to operate the system menu displayed when the SYS button is pressed Chapter 8 System Menu ...
Страница 144: ...This chapter describes the terminals and signals of the unit Chapter 9 External Interfaces ...
Страница 149: ...This chapter describes the dimensions and specifications of this product Chapter 10 Specifications ...
Страница 157: ...This chapter describes the setting menu table and terms Chapter 11 Appendix ...
Страница 173: ...Web Site http panasonic net Panasonic Corporation 2014 ...