Aicure ANUP5255V2
Setting
32
3
Press the “MANUAL” switch to open the shutter, and
conduct UV irradiation.
Setting mode
Manual intensity control 100%
000
UV intensity 3000 mW
Close
Open
End
▲
(Close)
Moves the intensity control shutter in the
direction that “closes” it. (The number of pulses is
incremented.)
▼
(Open)
Moves the intensity control shutter in the
direction that “opens” it. (The number of pulses is
decremented.)
SET (End)
Terminates the setting
The intensity of UV irradiation is measured at the opening and
displayed in the “UV Intensity” section.
4
Press the “MANUAL” switch to close the shutter.
・
If the indicated value is not a desired value, repeat Steps 2
to 4 until the desired value is obtained.
・
If the indicated value is a desired value, press the “SET”
button to determine the set value.
(When you return to the main screen, UV control is already
OFF. When irradiating at the settings of “Manual Intensity
Control”, open the shutter as-is.)
When UV control is switched to ON, the intensity
selected in “Intensity Selection” is restored. Even if
UV control is switched to OFF at this time, the
intensity of “Manual Intensity Control” is not restored.
Caution:
Displayed after
measurement