36
Palax KS45s
Translation
1-2017
The electric motor does not
start.
1.
Emergency stop button has
been depressed.
2.
The temperature switch has
tripped.
3.
Makes loud noise, but does
not start.
1.
Reset the emergency stop
button.
2.
Wait for 1-2 minutes; the
temperature switch then resets
automatically.
3.
The fuse has blown, replace it.
The electric motor stops easily
and the thermo-relay trips.
1.
Incorrect setting of the
thermo-relay.
2. Re-adjust the thermo-relay.
The electric motor rotates in
the wrong direction.
1.
Two phase conductors in the
wrong order.
1.
Switch the positions of two of the
conductors in the plug. Leave
the work to an expert!
The oil gets very warm.
1.
Too little oil.
2.
The cylinder hits the
bottom but the pressure is
not relieved, so the oil
circulates via the relief
valve.
1.
Top up oil.
2.
Adjust the cylinder stroke and
swing.
3.
Check the oil pump.
Содержание KS45S