Conventions Used in This DocumentAdministration
950-734-100-01, Revision 01
28
December 18, 1998
PLL-734 List 1
HDSL Alarm Types Screen
Allows the provisioning of the alarm types for all HDSL Alarms for both A and B RTs.
Table 10
lists the Alarm
Reports and
Table 11
shows the HDSL Alarms, the possible alarm Types, and the default settings. View the results
of these settings at the
“HDSL History Screen” on page 22
.
1
Select CONFIG from the menu and press
to display the submenu.
2
Scroll to the HDSL Alarm Types option and press
to view the screen.
3
At the
LOSW
field in the COLU Type column, press
to toggle to the desired value and a directional
key to move to the RT Type column. Continue until you have made all the desired changes.
4
Move to the
Accept HDSL Alarm Type Changes
button, and press
to accept the changes.
5
Press
to move up a menu level, or
+
to return to the PAU/PMU Main menu.
.
Table 10.
Alarm Reports
Settings
PAU/PMU
Reports
Fault LED
Affected
Main Summary
Listing
Alarm History
Updated
CR/MJ/MN
Yes
Yes
Yes
Yes
NA
No
No
No
No
NR
No
Yes
Yes
Yes
Table 11.
HDSL Alarms
Types
Description
Defaults
LOSW
HDSL link has lost synchronization.
MN
ES -15 MIN
Active if the 15 minute ES count equals or exceeds the threshold in the current 15 minute
interval.
MN
ES-24 HR
Active if the count equals or exceeds the threshold in the current 24 hour interval.
MN
UAS-15 MIN Active if the count equals or exceeds the threshold in the current 15 minute interval.
MN
UAS-24 HR
Active if the count equals or exceeds the threshold in the current 24 hour interval.
MN
MAR
Active if the margin equals or drops below the threshold.
MN