950-734-100-01, Revision 01
Administration
PLL-734 List 1
December 18, 1998
9
•
As the COLU continues with start-up mode, the SYNC LED Flashes indicating the HDSL line is attempting
to acquire synchronization. When complete, the SYNC LED is On. It takes approximately 2 to 3 minutes from
the system power-up until synchronization is achieved. If the first HDSL synchronization attempt fails, then
the system is powered down and put into the Metallic Fallback state and the BYPASS LED is On yellow. The
COLU attempts to synchronize every 5 minutes until synchronization is achieved. If it fails, it returns to
Metallic Fallback.
•
MARGIN LED is On yellow indicating the COLU signal-to-noise ratio is equal to or below the selected
signal-to-noise ratio threshold on the COLU. The MARGIN LED Flashes if the signal-to-noise ratio of the
HDSL line is equal to or below the selected signal-to-noise ratio threshold on the RT.
S
UBSCRIBER
D
ROP
T
ESTS
•
Initiate a test by applying a test voltage on the Tip at the COLU through an MLT set
•
With the VT-100 Terminal connected to the PAU or PMU maintenance port, select the Subscriber Drop Test
feature from the Test menu. Relays on the RT provide a path for performing a SDT. The results are reported
to the PAU or the PMU and presented as TA-909 resistive signatures.
A
DMINISTRATION
Performance monitoring is built into PG-Plus applications. You can access the VT-100 port of the PAU or the
PMU to review performance measurements that provide an indication of the quality of transmission to the
subscriber. You can perform system administration functions, such as alarm checking and clearing, configuration
changes, performance monitoring, and testing for the COLU through the COLU screens.
Connect a VT-100 terminal is connected to the RS-232 interface on the front panel of either the PAU or the PMU
to access the COLU screens. If the system does not respond, verify the following values are present:
•
VT-100 terminal Hardware Flow Control is set to On
•
XON/XOFF is enabled
•
ASYNC parameters: Data = 8, Parity = None, Start/Stop = 1.
For further information on connecting a terminal and accessing the screens refer to the PAU or the PMU or the
PAU or the PMU Technical Practice.
The factory defaults given in this document are standard factory defaults. You may have a
customized version of the product, in which case, refer to the PG-Plus Customized Factory
Defaults for the values appropriate to the product version you have.