COLU Summary Screen
This screen details the performance condition of the COLU and RT.
Table 4
defines the conditions that appear in
the Channel and HDSL Status fields.
1
Select Main from the menu bar and press
to view the COLU Summary screen.
2
Press
to move up a menu level, or
+
to return to the PAU/PMU Main menu. Refer to the
Performance and Alarms screens for a detailed description of data displayed in these areas.
Table 4.
System Status
State
Description
Channel Status
Open
No CO battery detected, Line Status Open. This status does not change except for Test status
Idle
CO battery detected and line is Onhook at RTs
Ringing
Line is ringing
Reversed
CO battery is detected with Tip and Ring reversed
Busy
Line is Offhook at RTs
Test
Line is under SDT or line is connected to PMU Test Access port
Channel Status for POTS during Metallic Fallback and HDSL Startup
N/A
Invalid until HDSL is in SYNC, or if Metallic Fallback has been disabled
Metallic Fallback
POTS #1 line status when system is in Metallic Fallback, if Metallic Fallback has been enabled
HDSL Status
HDSL Link Down
HDSL link is down and System is not in Metallic Fallback
Metallic Fallback
HDSL link is down and System is in Metallic Fallback
Start-up
System in start-up mode where the HDSL link is acquiring synchronization
Normal
System running normal where the HDSL link is synchronized and speech and signaling data are
flowing between the COLU and the RTs