Conventions Used in This DocumentAdministration
950-734-100-01, Revision 01
26
December 18, 1998
PLL-734 List 1
HDSL Options Screen
Allows the provisioning of HDSL options such as Periodic Power Up and Metallic Fallback.
Table 8
shows the
configured system option for both A and B RTs.
1
Select CONFIG from the menu and press
to display the submenu.
2
Scroll to the HDSL Options line and press
to view the screen.
3
Highlight the Channel 1 RLU Transmit Level line, press
to toggle to the desired value
4
Press a directional key to move to the next option. Continue until you have made all the desired changes.
5
Press a directional key to move to the
Accept Channel Option Changes
button, and press
to accept the changes.
6
Press
to move up a menu level, or
+
to return to the PAU/PMU Main menu.
Table 8.
HDSL Options Configuration Fields
Options
Description
Default
HDSL Periodic
Power Upn
When ENABLED, PG-Plus attempts to power up the HDSL line every five minutes or anytime
the HDSL pair is shorted for three seconds and then opened. Setting to DISABLED inhibits the
power-up sequence under any circumstances.
Enabled
HDSL Metallic
Fallbackn
When enabled, the system provides fallback to metallic operation on POTS channel 1 during
system failures. When disabled, the system provides no metallic connection during system
failures.
Enabled