Conventions Used in This DocumentAdministration
950-734-100-01, Revision 01
24
December 18, 1998
PLL-734 List 1
System Options Screen
System Options screen allows the provisioning of options such as ringing frequency, LCFO blocking, SDT, and
a System ID.
Table 6
shows the configured system option and the factory default value.
1
Select CONFIG from the menu and press
to display the submenu.
2
Scroll to the System Options line and press
to view the screen.
3
Highlight the desired field and press
to toggle to the desired value, or use a directional key to
move to the next option.
4
Press
to move to the
Accept System Option Changes
button, and press
to accept the
changes.
5
Press
to move up a menu level, or
+
to return to the PAU/PMU Main menu.
Table 6.
System Options Configuration Fields
Options
Description
Default
POTS Ringing
Frequency
The ringing frequency sent from the RT to the subscriber. Possible values include 20 Hz,
25 Hz, 30 Hz, and 50 Hz.
20 Hz
LCFO
Blocking
When turned on, this feature blocks Loop Current Feed Open (LCFO) signalling from being
sent to the RT. When activated, LCFO blocking maintains battery feed at the RT during an
LCFO event.
Off
SDT
Compatibility
Specifies whether the PG-Plus initiates and operates with MLT or 4TEL loop test systems.
Select the test type according to the loop testing system in use. Possible values include Off,
MLT, and 4TEL. Craft initiated SDTs work in any selection.
Off
PG-Plus
System ID
Configurable identification string for system. This string can be up to 24 characters.
Because the System ID is visible at every COLU screen, it is easy to know which COLU
screens are displayed. There are no special rules for changing the System ID. Any printable
character, including space, is valid.
PG-Plus
System