950-734-100-01, Revision 01
Conventions Used in This DocumentAdministration
PLL-734 List 1
December 18, 1998
25
System Alarm Types Screen
Allows the provisioning of the alarm types of all system alarms including incompatible COLU and RT, No RT
Software, and input power missing.
Table 7
shows the System Alarm fields and the default settings. You can view
the results of these settings from the
“System History” on page 21
.
1
Select CONFIG from the menu and press
to display the submenu.
2
Scroll to the System Alarm Types option and press
to view the screen.
3
With the COLU RT Mismatch line highlighted, use the
to toggle to the desired value for the
Alarm Type, then press a directional keys to move to the next option.
4
When you have made all the desired changes, press a directional keys to move to the
Accept System
Alarm Types Changes
button, and press
to accept the changes.
5
Press
to move up a menu level, or
+
to return to the PAU/PMU Main menu.
Table 7.
System Alarm Types
Alarms
Description
Default
MISMATCHn Incompatible COLU and RT units have been installed. For example, a Dual 2 POTS COLU has been
connected to a 2 ISDN RT.
MN
NORLUSWn
RT has no application software and is awaiting software download.
MN
MISPWRA
COLU detected missing A -48 Vdc power source. If power is verified at the unit, then the unit must be
replaced, because it has a blown fuse.
NA
MISPWRB
COLU detected missing B -48 Vdc power source. If power is verified at the unit, then the unit must be
replaced, because it has a blown fuse.
NA
BKUPMEMP
EEPROM Failure
MN