3.2.4 POWER FAULT LED On - 5645 Displays Power Fault
Procedure
Follow this procedure if the 5645 POWER FAULT LED lights
during operation:
Internal failure.
Contact Pacific
Scientific.
Remove 120 V ac and
then the motor connector
(J1).
Warning
Do not disconnect the
motor connector with power
still connected. The motor
terminals contain
hazardous voltage when
power is connected.
Reapply power, POWER
FAULT LED goes off?
Cable or internal
failure. Contact
Pacific Scientific.
5645 power fault fixed.
No
Yes
No
Yes
Check cables for shorts.
Check connections per
sections 2.5.1 and 2.5.2.
Reconnect cables.
Reapply power. POWER
FAULT LED goes off?