3.2.1 POWER LED Not On - 5645 Does Not Power Up
Procedure
Follow this procedure if the 5645 POWER LED will not light
when power is applied:
Connect 120 V ac
(section 2.5.2).
Apply correct voltage.
Is 120 V ac applied?
Replace fuse and retry.
Is 120 V ac within
operational range (98 to
132 V)?
Internal failure. Contact
Pacific Scientific.
Are fuses OK (see
following procedures)?
No
Yes
No
Yes
No
Yes