CAUTION
Do not pre-tin (solder) the tips of the cables going into the PCD
connector. This can result in a loose connection.
3. Remove power from the 5645.
WARNING
Always remove power before making or removing connections
to the unit. The motor terminals have high voltage present
when the 5645 is On.
4. Plug the mating connector firmly into the 5645.
5. Connect the cable shield to 5645 ground, if applicable.
6. Plug the other mating connector into the motor.
7. Switch On the 5645.
2.5.1.2 8-Lead Motor, Series Connected
Introduction
For an 8-lead motor to be wired in series, build and install the
cable as follows:
Cable
requirements
Use 16- to 14- gauge stranded wire for the cabling. Obtain cable
with each winding pair (see diagram) twisted at about 3 to 4 turns
per inch (1 to 1.5 turns per centimeter). Make sure the cable
contains a lead for grounding. As an option, the cable may be
shielded to reduce radiated noise.
2 - 14
5645 Installation and Hardware Manual
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com