PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the Pacific Energy, FP30 and FP30AR Zero Clearance Wood
Fireplace.
This heater meets the 2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold
after May 15, 2015. Model FP30 Series B: 2.5 g/hr.
Under specific test conditions this heater has been shown to deliver heat at rates ranging from 14,600 to 38,600 Btu/hr.
SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For your safety, follow the installation
instructions. Contact local building or fire officials about restrictions and installation inspection requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
Experience will give you the right settings for proper combustion and efficient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With
practice, you will become proficient in operating your heater and will obtain the performance for which it was designed.
EPA Certified Emissions
2.5 grams per hour
LHV Tested Efficiency 1
76.8%
HHV Tested Efficiency 2
63% (EPA Default)
EPA BTU Output 3
14,600 to 38,600 Btu/hr
Peak BTU/Hr Output 4
99,000 Btu/hr.
Maximum Wood Length
20 inches
Ideal Wood Length
18 inches
Fuel
Seasoned Cord wood
1 Weighted Average Lower Heating Value (LHV) efficiency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efficiency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efficiency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
4 The Peak BTU/hr is based on efficiency using CSA B415
Performance testing of solid-fuel-burning heating appliances,
the Maximum one hour High burn rate from the High Burn EPA
test and the BTU content of cord wood (8600 btu/lb).
Efficiency and BTU Output
3
100000811_200418-48
FP30 Series B