BLOWER ASSEMBLY
TRANSITION BOOT
B-VENT HEAT DUCT
Figure 26: Blower installation.
Blower Casing
finishing edges
Blower Casing
finshing edges
Mounting Tabs
Mounting Tabs
Figure 27: Blower details.
Outlet Grill Mounting
Holes
Face Plate
Figure 28: Grill mounting holes.
THE REMOTE HEAT KIT BLOWER ASSEMBLY MUST
BE INSTALLED SO THAT ANY EDGE OF THE BLOWER
CASING/OUTLET GRILL IS A MINIMUM OF:
- 12"(305mm) FROM THE CEILING OR ADJUST WALLS
- 36"(914mm) FROM THE FLOOR
5. Locate the Remote Blower Assembly in the desired wall
location, following the specifications listed below and
secure to the framing using the mounting tabs on the
casing."Figure 27: Blower details."
6. Attach the 10”(254) X 3 1/4”(83mm) Transition Boot to
the Remote Blower Assembly and seal with aluminium
duct tape. Run 6” diameter approved Type “B” flexible or
ridged gas vent pipe (vent pipe is not included with this
kit) between the blower and the fireplace. Fasten in place
with screws and seal with aluminium foil tape.
7. Connect the wiring as per the directions and wring dia-
gram in "Remote Heat Kit Wiring" on page 28.
8. Locate the make-up air inlet as per the owner's manual in a desired location in the wall. Anchor to the
wall studs using scre
9. Drywall and facing material must not cover the opening in the blower assembly. Remove the Face Plate.
Cut the drywall so the egdes butt up against the outside of the blower casing edges (Figure 27), top, bot-
tom and sides.
10. Re-install the Face Plate (Figure 28) and then attach the Outlet grill(s) over the outlet(s) Face Plate using
the screws provided by aligning the screws for the outlet grill with the holes in the casing face plate.
11. Install the Inlet grill(s) over the chase inlet opening(s) after any decorative finish has been applied.
27