Firebrick Installation Instructions
This package contains 19 full-size firebricks, as well as 3 various cut-size bricks. With the fireplace in the
upright position, install firebricks as follows:
1. Place the firebricks on the bottom of the unit first. Use a total of 9 full-size (A) and 1 cut brick (C).
2. Next install the rear firebricks, 4 full-size (A) bricks as shown.
3. Finally install 3 full-size bricks (A) and 1 cut firebrick (B) on each side as shown.
A
A
B
C
B
Figure 37: Firebrick layout.
ITEM
SIZE
PART NUMBER
A
9” X 4 1/2” X 1 1/4”
(230 mm x 115 mm x 32 mm)
5096.99
B
9” X 3 1/2” X 1 1/4”
(102 mm x 115 mm x 32 mm)
3245.501
C
7 1/4” X 4 1/2” X 1 1/4”
(184 mm x 115 mm x 32 mm)
245.001