WARNING: ALL ELECTRICAL WIRING MUST BE DONE BY A QUALIFIED ELECTRICIAN.
NOTE: For best results, the remote heat kit blower/s should be wired to a separate switch or speed controller
in the room that the outlet is in. If the outlet(s) are mounted in the chase they could be wired on the same
switch or speed controller as the Fireplace Blower.
Consult local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or
in the USA,the National Electrical Code, ANSI/NFPA 70 (Latest Edition).
The Remote Heat Kit blower's electrical rating: 120V, 60HZ, 80 watts. For your protection against shock
hazard, use only a properly grounded electrical supply.
This kit includes a junction box, rheostat and cover plate. The junction box should be mounted in a convenient
location away from the fireplace.
Remote Heat Kit Wiring
Hot (black)
Neutral (white)
WALL SWITCH/
SPEED CONTROLLER
Blower
Ground
Ground
Use only copper conductors
Figure 29: WODC.RHkit wiring diagram.
28
100000811_200418-48
FP30 Series B
Содержание FP30AR
Страница 47: ...47 100000811_200418 48 FP30 Series B...