Split network interfaces are created by removing the desired Ethernet ports from the bond
configuration and treating them as individual network interfaces. The following procedure
removes the Ethernet ports from the bond configuration and enables one of them in DHCP
mode.
CAUTION:
In addition to removing the Ethernet ports from the bond configuration, the bond
interface MUST be disabled as well. Failure to disable the bond interface causes the
QuikStation to become inaccessible over the network. This condition requires a network reset
using a specially configured USB drive. Contact Overland-Tandberg Technical Support.
1.
Remove the
Ethernet ports
from the bond configuration.
a.
Select
System Settings > Network
.
b.
Click
Modify Bonding
.
c.
At the
Modify Bonding
dialog, check both of the None boxes.
d.
Click
Change
to unbond the ports.
2.
Disable the bond port after Ethernet port removal.
After removing the Ethernet ports from the bond interface, the bond interface MUST be
selected and disabled.
a.
Click the
Edit gear
icon for the bond interface.