The RDX QuikStation has multiple network interfaces. These may be used as separate
connections or may be “bonded” together to act as a single connection to protect against failure
or to improve throughput.
NOTE: If a port is not connected to the Ethernet, be sure to set the port IPv4 setting to Disable this
interface, and set the bond for that interface to None. If this is not done, it will take longer for
the system to boot and, under certain circumstances, ports that are connected may not
function properly.
To configure network information for the RDX QuikStation:
1.
Select
System Settings > Network
.
The
Network Settings
dialog window opens, showing only those interfaces that are not
part of another bonded interface.
2.
If desired, you can modify the
host name
.
The default RDX QuikStation host name uses “vtx1u” (QuikStation 4) or “vtx2u”
(QuikStation 8) plus the last five digits of the unit’s serial number.
3.
To change the way in which the network interfaces are bonded, click
Modify Bonding
.