![Oval MAG-OVAL III MGS Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/oval/mag-oval-iii-mgs/mag-oval-iii-mgs_instructions-manual_1662164045.webp)
C
−
102-1-E
45
18.2 Diagnosing All Items
This function executes self-diagnosis of all four items and displays the results.
This function is activated by self-check function "CHECK" of the Setup mode (layer code 14-00).
When diagnosis is completed, the results are displayed. If no abnormality is found, "Good" is displayed. If
abnormality is found in any of diagnosis items, error or alarm No. of the corresponding item is displayed.
For the details of error/alarm, refer to "20. ERROR/ALARM STATUS LIST".
Started by "Press and hold ENT".
Ex. Er-21
Abnormality found in
coil, exciting circuit
"Press and hold SEL" returns to the original screen.
The screen during self-diagnosis.
An item in self-diagnosis operation is
indicated on the bottom row of LCD.
Display changes in the sequence of
Cirt.C
→
CoiL.C
→
SiGL.C
→
EnnPy.C.
Self-diagnosis menu
Press and
hold ENT
Press and
hold SEL
No abnormality
Abnormal