Measurement range
Flow measurement damping
Low cut
Low cut hysteresis
F.dAmP
F.Prm2
F.Prm3
00-00
01-00
02-00
03-00
04-00
05-00
06-00
07-00
08-00
09-00
10-00
11-00
12-00
13-00
14-00
PAS.wd
02-01
02-02
02-03
02-04
dSP.St
F.Prm1
diAG.S
LP.tSt
A.trim
CHECK
A.Out
P.Out
Er.Out
ALArm
04-01
04-02
04-03
04-04
04-05
Nominal diameter
dimtr
Zero point
CAL.0
Calibration factor
CAL.F
DC type basic cycle
dC.bAS
Coil exciting frequency
dr.Frq
S.Out
St.SEL
Parameter secondary item
Lo.Cut
LC.HyS
Fixed conversion factor
02-05
Con.FC
FL.rnG
Noise failure suppression
Auto gain compensation
AG.Com
03-01
03-02
Flow direction
03-03
FL.dir
In.SuP
Content of parameter
Default
Setting range
0.50 to 99.99s (seconds)
On (Valid), OFF (Invalid)
OFF
OFF
1.0000E0
5
As
specified
0.50
0.0 to 100.0%
Can change the full scale of % flow rate (max. measured flow).
Can change damping time constant for flow measurement.
Affects the instant flow rate display and analog output.
* Time constant is the time required for the instruction to reach approx. 63% in the step response.
Can change the low cut flow. As flow measurement below setting is not carried out, this
is effective for preventing error output due to fluid oscillation (noise) at zero flow rate.
Setting is available with the rate (%) to the measurement range.
Can provide the low cut setting with 5% hysteresis.
Ex.: At the time of 5% low cut, cutting occurs up to 10% for the measurement
range as flow volume is increased. It is cut to 5% at the down time.
Can set the conversion factor of flow rate.
Used for fixed density conversion, etc. for conversion to mass flow rate.
0.0000E0 to 9.9999E9
(5 significant 1 exponent digit)
Content of parameter
Default
Setting range
On (Valid), OFF (Invalid)
* As this model uses highly reliable parts, it is
unnecessary to set
"
Valid
"
in normal case.
PoS.FL
100
Regulates instant flow rate variation due to impulse type noise, etc.
The range for permitting variation is set by % to max. flow measured.
Automatically calibrates and compensates the variation of transmitter internal circuit due to ambient temperature, etc.
When this feature is validated, measurement is suspended (display and output are held) for approx. 0.5 sec. at intervals
of 24 min. Therefore, do not use this flowmeter in the system requiring response such as in batch measurement.
Sets the flow direction of measured fluid with respect to the flow direction (arrow
marking) of the probe.
1 to 100%
* 100% : Function invalid
"
PoS.FL
"
(Positive flow),
"
nEG.FL
"
(Negative flow)
Content of parameter
Default
Setting range
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Displays exciting frequency of probe coil.
* Cannot be changed.
Displays the nominal size of probe.
* Cannot be changed.
Displays zero point constant of probe.
* Cannot be changed.
Displays calibration factor of probe.
* Cannot be changed.
Displays measurement reference frequency at the time of DC power on. (Only DC power model)
* Cannot be changed.
Value appropriate for your environment is
set at the time of factory shipment.
Appropriate value is set at the time of
factory shipment.
Appropriate value is set at the time of
factory shipment.
Appropriate value is set by the calibration of
actual flow at the time of factory shipment.
Appropriate value is set by the calibration of
actual flow at the time of factory shipment.
*****
*****
0.5 to 10m/s
by flow velocity conversion
m/s
modE
%
**.***
**.**
**.**
"SEL"
"Press and hold SEL"
"Press and hold ENT"
Other
Displays instant flow rate
Displays % flow rate
Displays flow velocity
Setup mode
Set flow parameter 2
Set flow parameter 3
Parameter major item
[Top row display] Selects display
Enter password
Set display
Set flow parameter 1
Set self-diagnosis
Loop test
Analog output trim function
Self-check function
Set analog output
Set pulse output
Set error output
Set alarm
Set status output
Select status output object
ENT
Total flow
Resettable total flow
[Bottom row display] Displays total flow
Parameter name
Layer code (Major item ― Secondary item ― Third item)
Parameter
display symbol