APPENDIX A: TECHNICAL SPECIFICATIONS
Channels
Two separate channels: one for stimulus and one for masking.
Frequencies
Air, Free Field: 125-250-500-750-1000-1500-2000-3000-
4000-6000-8000 Hz.
Bone:
250-500-750-1000-1500-2000-3000-4000-6000 Hz.
Masking
Contralateral and Ipsilateral. Binaural st masking.
White Noise, Speech Noise and Narrow Band Noise.
Attenuator Range
-10 to +149 dB in 5 dB steps with Range Extender function.
Resolution: 1 dB or 5 dB steps.
Fully clickfree operation over entire range.
Hearing Level Range
Maximum output is limited by transducer capability. Typical
values are:
Air:
-10 to 120-125 dB HL at 500-6000 Hz
Bone:
-10 to 70-80 dB HL at 500-4000Hz.
External Inputs
Talkover
Dynamic or electret, for speech audiometry
Microphone:
or patient communication.
Patient Mic.:
Dynamic or electret.
CD/Tape1:
Sensitivity 0.1 - 3.0 VRMS, 47 kOhm.
CD/Tape2:
Sensitivity 0.1 - 3.0 VRMS, 47 kOhm.
Outputs
Phones:
Air Conduction.
Bone:
Bone Conduction.
Insert:
Insert Phone for masking.
Free Field:
F.F Loudspeaker via external Amplifier.
Output Voltage:max. 3 Vrms.
Source Impedance:
500 Ohm.
Standard Functions
Speech:
Stimulus via Microphone or CD/Tape1.
Masking:
White Noise, Speech Noise or external CD/Tape2.
Ipsi, Contra or Bin. S+M.
Tone Switch:
Normal or Reverse operation.
Pure Tone:
Manual or 1.5 sec. Tone Duration.
Pulsing Rate:
User-programmable (Range: 1.5 to 3.5 Hz).
Warble:
Frequency Modulation 3.7
$
5%.
Modulation Waveform: traingular.
Modulation Range: 5%.
L/R Shift:
Automatic switching of all selected parameters
from left to right channel and vice versa.
HL Level Lock:
Locking of masking level to stimulus level
at any preselected interval.
Tone Lock:
On/off, internal tone switch synchronization.
Special Functions
SISI Test:
Display shows: Presentation counter, Patient Score
counter with current Score Percent constantly indicated.
Increments of 1 or 5 dB.
Interrupt/Reset function. Initiated by Tone Switch.
Fowler Test:
Alternate Binaural Loudness Balance (ABLB) Test.
Stenger Test:
Binaural Tone Stimulation.
Rainville Test:
Bone Conduction Masking.
User Functions
5 user-programmable functions available for quick test retrieval.
User setups are stored in a non-volatile memory (EEPROM).
Display
Alphanumeric Transflective LCD with CFL Backlighting.
2 rows of 40 characters with Cursor. Screen dimensions 155x16 mm.
þ
MIDIMATE 622 OPERATION MANUAL
Appendix A: Technical Specifications
77
Содержание MADSEN Midimate 622
Страница 1: ...Midimate 622 Clinical Diagnostic Audiometer User Manual Doc no 7 25 9000 09 Part No 7 25 900 0459 ...
Страница 16: ...10 MIDIMATE 622 OPERATION MANUAL 2 Installing Midimate 622 ...
Страница 18: ...Fig 3 The Selection Tree MIDIMATE 622 OPERATION MANUAL 3 General Description 12 Menu Menu Menu ...
Страница 54: ...This page has intentionally been left blank MIDIMATE 622 OPERATION MANUAL 7 Speech Audiometry 48 ...
Страница 70: ...This page has been intentionally left blank MIDIMATE 622 OPERATION MANUAL 10 Power On Options 64 ...
Страница 74: ...This page has intentionally been left blank MIDIMATE 622 OPERATION MANUAL 12 Calibration 68 ...
Страница 101: ...ZODIAC 901 Connection To 74 ZODIAC 901 Printout To 59 73 MIDIMATE 622 OPERATION MANUAL Subject Index 95 ...