89
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
4.
Turn the parameter adjustment knob, and change the setting value.
5.
Press the CANCEL key.
⇒
The setting of internal function completes, and the LCD display returns to MENU.
6.7.2
Detailed information on internal functions
This section explains the detailed information of internal functions in the order of function No.
6.7.2.1
F1: Standard/Extended cable mode
Sets the welding control status for extended cables for the application of STANDARD mode. This function is available
when travel speed is set to "STANDARD" and WELDING METHOD is set to "DC".
Extending the cables at the base metal side/torch side or power cables such as torch cables can cause extraordinary volume
of spatter. When this happens, turning this function ON (extended cable mode) can improve the status.
•
"ON": Extended cable mode
Set to "ON" for the length of extension cable longer than 99 ft (30 m). Set to "ON", "DC (extended)" will be displayed
at the welding method menu in HOME screen.
•
"OFF": Standard mode
T I P S
• In using the welding power source in the "HIGH" mode, the setting of this function is set to "OFF" and
cannot be changed.
• When the status is not improved even by setting of this function to "ON", combined use of the voltage
detection cable is recommended.
When using the voltage detection cable, set the internal function F38 (Arc voltage direct detection
switching) to "1". (
6.7.2.28
-
F38: Arc voltage direct detection switching)
6.7.2.2
F2: Switching functions with remote control
Sets the functions to be allocated to the switching knob of the analog remote control.
The selectable functions are “1” through “6” as shown in the below table. No function will be allocated if set at “0”.
⇒
The set value is activated as it is changed.
Setting
Function
0
No function
1
Crater setting
(
6.6.4 Crater setting
)
2
Gas check
(
5.3 Power ON and Gas Supply
)
3
Constant penetration
(
6.6.8 Penetration control
adjustment
)
4
Tack start
(
6.7.2.40 F54 Tack start process
)
5
Reading welding conditions with remote control
(
6.7.2.32
F44: Reading welding conditions with remote control
)
6
Welding condition
(
6.6.2 Setting welding conditions
)