Alarm setting switching
OFF/ON
OFF
Sets the output status when an error of the alarm level
is detected:
OFF: Ineffective
ON: Stops the output
-
F20
Low input voltage
detection level
140 to 460
(*1)
160 (V)
Adjusts the low primary input voltage detection level.
-
320 to 460
(*2)
3 0 (V)
-
F21
Ma imum cooling fan operation
OFF/ON
OFF
Sets the operation mode of cooling fan:
OFF: Economical operation
ON: Rotates the fan at ma imum speed at all time
-
F22
SUS E pulse switching
OFF/ON
ON
Two types of welding performances can be selected in
pulse welding of stainless steel.
OFF: Spatter generation can be suppressed.
ON: The root of the groove can be aimed with ease and
incomplete penetration can be suppressed.
-
F23
Sleep mode
switching time
0 to 10
0
Sets the time until the welding power source enters into
sleep mode:
0: OFF
1 to 10: 1 min to 10 min
-
F24
Wire feeding speed setting
OFF/ON
OFF
Sets the criteria for welding condition:
OFF: based on current
ON: based on wire feeding speed
-
F25
E ternal output 1 setting
0/4
0
Sets the functions of output terminal of the
programmable I/O.
-
F26
E ternal output 2 setting
F2
E ternal output 3 setting
F28
E ternal output 4 setting
F29
E ternal input 1 setting
0 to
0
Sets the functions of input terminal of the
programmable I/O.
-
F30
E ternal input 2 setting
0
F31
E ternal input 3 setting
0
F32
E ternal input 4 setting
0
F33
Inhibition ratio display for
[s ueeze] detection
-
-
When F33 is selected the [S ueeze] detection
inhibition ratio (%) is displayed on the right digital meter.
This function is not configurable.
-
F34
Automatic correction of
[s ueeze] detection sensitivity
OFF/ON
ON
Sets ON/OFF of the automatic correction function of the
[S ueeze] detection sensitivity:
OFF: No automatic correction
ON: With automatic correction
㾎
F35
Saving [s ueeze]
detection sensitivity
OFF/ON
OFF
Sets whether to save the [S ueeze] detection sensitivity
at completion of welding:
OFF: Not to save
ON: To save until the ne t welding starts
㾎
F36
Spatter control P1P
-100 to 100
0
Sets the control parameters for spatter control.
㾎
F3
Spatter control P2P
F38
Arc voltage direct detection
switching
0 to 2
0
Switches the position of arc voltage detection.
0: Standard
1: When directly detected at the base metal side
2: When using the straight-polarity (wire negative) wire
-
F39
Output current gain adjustment
-10 to 10
0 (A)
Adjusts the current output value.
Is used when calibration of welding
current or voltage
is needed.
-
F40
Fine adjustment of Output
current gain
-0.99 to 0.99
0.00 (A)
F41
Output voltage gain adjustment
-1.0 to 1.0
0.0 (V)
Adjusts the voltage output value.
Is used when calibration of welding
current or voltage
is needed.
-
F42
Fine adjustment of output
voltage gain
-0.09 to 0.09
0.00 (V)
F43
CAN ID
1 to 16
1
Sets CAN ID numbers to be used in the PC monitoring
system etc.
-
F44
Reading welding conditions with
remote control
OFF/ON
OFF
Sets whether to read 1 to 10 of the welding
conditions stored on the memory via the analog remote
control:
OFF: Not to read
ON: Reads
-
No.
Function Name
Setting range
Initial value
Explanation
Memory