6.7.2.53 F71: Interval welding function
This function repeats arc ON/OFF to control the heat input.
•
“ON”: Enables the function. When this function is enabled, “: Interval” will be displayed at the end of CRATER-FILL
CONDITION in the Home Screen, and internal functions F72 and F73 will be enabled.
(Example) CRATER OFF: Interval
•
“OFF”: Disable the function.
T I P S
• When this function is set to “ON”, the setting of “CRATER-FILL: OFF” will be selected
automatically, disabling other welding modes. (The “CRATER-FILL” Menu will not function.)
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or "5" (Loading
welding condition).
6.7.2.54 F72: Setting Arc-ON time (Interval function)
Sets the arc-ON time in the Interval welding function.
•
Set the arc-ON time in the range of 0.20 to 9.99 seconds.
6.7.2.55 F73: Setting Arc-OFF time (Interval function)
Sets the arc-OFF time in the Interval welding function.
•
Set the arc-OFF time in the range of 0.20 to 9.99 seconds.
6.7.2.56 F77: Welding result control function identification numbers
Sets the identification numbers of welding power source when using welding result control function. The identification
number set in this function become the part of file name when backing up the data of welding result control function.
(
7.3.4
-
Welding Result Control Function)
•
Setting range of identification number: 1 to 999.
6.7.2.57 F78: Prevention of unintended torch switch operation
Sets whether or not to output the error code when welding is not performed for a certain time after the pre-flow to avoid
an unexpected torch switch operation.
•
[ON]: If welding is not performed for five seconds after the pre-flow, Error code “E-011” is displayed on the left and
right digital meters and the output of the welding power source stops.
•
[OFF]: disables the function. (
9.1 Action in Case of Error)
6.7.2.58 F79: Switching of CAN communication connection device
Set the connection device to be used for the CAN communication.
Set to "0" to use the Digital Remote Control Box.
Set to "1" to use the Digital panel (Attached to the wire feeder) and Intelli torch.
Set to "2" to use the Push-Pull torch.
Set to "3" to use the Inline Assist feeder.
The Digital panel can also be used with "2" and "3".
This function is effective when any one of "0" (Semi-auto mode), "1" (Automatic machine 1 mode), and "2" (Automatic
machine 2 mode) is selected for F4 (Auto/Semi-auto mode).