6.7.2.43 F61: Fine adjustment of pulse peak time
This function allows fine adjustment of the standard pulse peak time; by setting the adjustment value, finely adjusted
pulse peak time can be obtained.
Moreover, in the pulse condition of the wave pulse welding at HIGH side, fine adjustment is available to the standard
pulse peak time at HIGH side by setting the adjustment value.
Example of current waveform of wave pulse welding (
6.7.2.47
-
F65: Fine adjustment of L base current)
Set the adjustment value in the range of -1.5 to 1.5 ms.
Fine adjustment of unit pulse condition (
6.7.2.42
-
F60: Fine adjustment of pulse peak current, <Fine adjustment of unit
pulse condition>)
Example of current waveform of wave pulse welding (
6.7.2.47
-
F65: Fine adjustment of L base current)
6.7.2.44 F62: Fine adjustment of base current
This function allows fine adjustment of the standard base current; by setting the adjustment value, finely adjusted base
current can be obtained.
Set the adjustment value in the range of -60 to 60 A.
Fine adjustment of unit pulse condition (
6.7.2.42
-
F60: Fine adjustment of pulse peak current, <Fine adjustment of unit
pulse condition>)
6.7.2.45 F63: Fine adjustment of L pulse peak current
This function allows fine adjustment of the standard pulse peak current at LOW side in the pulse condition of the wave
pulse welding; by setting the adjustment value, finely adjusted pulse peak current at LOW side can be obtained.
Set the adjustment value in the range of -150 to 150 A.
Fine adjustment of unit pulse condition (
6.7.2.42
-
F60: Fine adjustment of pulse peak current, <Fine adjustment of unit
pulse condition>)
Example of current waveform of wave pulse welding (
6.7.2.47
-
F65: Fine adjustment of L base current)
6.7.2.46 F64: Fine adjustment of L pulse peak time
This function allows fine adjustment of the standard pulse peak time at LOW side in the pulse condition of the wave pulse
welding; by setting the adjustment value, finely adjusted pulse peak time at LOW side can be obtained.
Set the adjustment value in the range of -1.5 to 1.5 ms.
Fine adjustment of unit pulse condition (
6.7.2.42
-
F60: Fine adjustment of pulse peak current, <Fine adjustment of unit
pulse condition>)
Example of current waveform of wave pulse welding (
6.7.2.47
-
F65: Fine adjustment of L base current)
6.7.2.47 F65: Fine adjustment of L base current
This function allows fine adjustment of the standard pulse base current at LOW side in the pulse condition of the wave
pulse welding; by setting the adjustment value, finely adjusted pulse base current at LOW side can be obtained.
Set the adjustment value in the range of -60 to 60 A.
Fine adjustment of unit pulse condition (
6.7.2.42
-
F60: Fine adjustment of pulse peak current, <Fine adjustment of unit
pulse condition>)
<Example of current waveform of wave pulse welding>
P
ulse
c
ondition
at
H
IG
H
side
P
ulse
c
ondition
at
LO
W
side
P
ulse
c
ondition
at
H
IG
H
side
Current
value
Time
P
ulse
pea
k c
urrent
at
LO
W
side
P
ulse
pea
k c
urrent
at
H
IG
H
side
B
ase
c
urrent
at
H
IG
H
side
B
ase
c
urrent
at
LO
W
side