C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
36
1.
Connect the torch cable and the voltage detection adapter to the wire feeder.
2.
Cut the voltage detection cable for base metal side to a suitable length.
3.
Connect the voltage detection cable for base metal side to the base metal.
4.
Connect the voltage detection cable for base metal side to the voltage detection terminal of the wire feeder.
T I P S
•
Voltage detection cable for base metal side can also be connected to the direct voltage detection
terminal for base metal of the welding power source. When using the welding power source by
lifting with hoisting equipment, connect the voltage detection cable for base metal side to the
direct voltage detection terminal for base metal side.
For reducing the influence of inductance noise, take note of the following caution on connection and wiring example of
voltage detection cable.
Connection for voltage detection cable is complete. Procedure is followed by “4.2.7
-
Connection of shield gas”.