59
Chapter 5
W
elding Operation
P
ERFORMING
W
ELDING
O
PERATION
W
ELDING
O
PERATION
C
HAPTER
5
1.
Press the DISPLAY CHANGE key.
B
The displays of the left/right digital meter switches to the set values.
B
The LED for the welding sequence changes to the light-up mode.
2.
Adjust the welding current.
●
When the LED above the left digital meter is off, press the parameter adjustment knob to light up the LED. (In the
adjustment by the remote control, this operation is not necessary.)
●
Turn the parameter adjustment knob (for the remote control, the welding current adjustment knob) to adjust the
welding current.
3.
Adjust the welding voltage.
•
There is no voltage adjustment for DC TIG welding and DC STICK welding.
●
When the LED above the right digital meter is off, press the parameter adjustment knob to light up the LED. (In
the adjustment by the remote control, this operation is not necessary.)
●
Turn the parameter adjustment knob (for the remote control, the welding voltage adjustment knob) to adjust the
welding voltage.
4.
Press the DISPLAY CHANGE key.
B
The displays on the left/right digital meters return to the display of current/voltage in welding.
B
The LED for the welding sequence returns to the flashing mode.
T I P S
•
When no operation is performed for approximately 5 seconds, the display will return to the
one showing current/voltage in welding.
•
Using the internal function (F48) enables to increase/decrease the welding current by the
torch switch operation. (It is available only with the crater set to on and in the welding
condition.) (
6.7
-
Setting Internal Functions)
•
When “SYN.” is selected in the “VOLT. ADJUST” Menu, the voltage is automatically set to the
value according to the current.
>㸯@
>㸰@
>㸱@
Parameter
adjustment knob
UNIT CHANGE key
Welding
power source
DISPLAY CHANGE key
Analog remote control
(Optional accessories)
Welding current
adjustment knob
Welding voltage
adjustment knob