SECTION 6 - TROUBLESHOOTING
6-40
31215825
Platform (Mast) Won’t Stay Elevated
Overview Of Procedure
The following procedure requests that the lift down, dump, and pump internal valves be checked to see if any are stuck open, it also
examines the lift down and dump valve circuits. Also suggests that the lift cylinder packing could be leaking internally.
Check For These Obvious Conditions First:
• Manual descent valve is closed tight.
Platform (Mast) Descends Too Slowly
Overview Of Procedure
The following procedure examines the mast some hydraulic components for obstructions and defects.
Table 6-45. Platform (Mast) Won’t Stay Elevated
STEP
ACTION
SPEC
YES
NO
1.
Is the lift down valve stuck open?
—
Repair or Clean
Valve
Go to Step 2
2.
Lift down valves could be open due to incorrect electrical signal.
—
Check Pump
Valve Electrical
Circuit
Go to Step 3
3.
Oil could be passing around the lift cylinder bore packing.
—
Replace or
Rebuild the Lift
Cylinder
—
Table 6-46. Platform (Mast) Descends Too Slowly
STEP
ACTION
SPEC
YES
NO
1.
Check mast slide pads shimmed to tight.
—
Reshim Mast
Go to Step 2
2.
Is there an obstruction in the mast?
—
Remove
Obstruction
Go to Step 3
3.
The lift cylinder packing could be too tight in the bore of the cylinder
barrel.
—
Rebuild or
Replace Cylinder
Go to Step 4
4.
Check if the lift down valve is opening completely.
—
Clean or Replace
Valve
Go to Step 5
5.
Is there a restricted hydraulic line (smashed)?
—
Replace Hydraulic
Line
Go to Step6
6.
Check the flow valve in the cylinder valve block for a restriction, i.e.
dirt.
—
Clean or Replace
Flow Valve
—
Go
to
Discount-Equipment.com
to
order
your
parts