Maintenance
&
Troubleshooting
46
SMLC
‐
004a
SMLC
Troubleshooting
No
LEDs
Lit
on
SMLC
Verify
that
there
is
AC
power
to
the
unit.
Verify
that
the
AC
voltage
on
the
input
power
terminal
block
is
the
appropriate
level
(either
115
or
230
VAC).
SMLC
Does
Not
Complete
the
Power
Up
Sequence
If
the
SMLC
doesn't
complete
the
power
up
sequence,
gather
the
information
listed
below
and
call
the
ORMEC
Service
Department.
•
SMLC
model
number,
hardware
version
number
&
serial
number,
available
on
the
sticker
on
the
left
side
of
the
unit.
•
With
the
SMLC
in
the
incomplete
power
up
sequence,
note
the
status
of
the
LED's
located
on
the
front
of
the
controller.
24VDC,
Run,
Fault,
Watchdog,
User,
and
System.
•
The
SMLC
firmware
version:
•
If
you
are
able
to
communicate
with
the
SMLC
after
resetting
the
unit
or
cycling
power,
the
SMLC
firmware
version
can
be
determined
by
using
ServoWire
Pro's
SwMonitor.
Содержание SMLC 160
Страница 2: ...ServoWire Motion Logic Controller Manual General Description ii SMLC 004a...
Страница 4: ......
Страница 28: ...ServoWire Motion Logic Controller Manual System Power Wiring Interlocks 20 SMLC 004a...
Страница 38: ...ServoWire Motion Logic Controller Manual WAGO I O Installation Operation 30 SMLC 004a...
Страница 46: ...ServoWire Motion Logic Controller Manual Getting Started 38 SMLC 004a...
Страница 52: ...ServoWire Motion Logic Controller Manual Maintenance Troubleshooting 44 SMLC 004a...
Страница 58: ......
Страница 60: ...ServoWire Motion Logic Controller Manual Appendix A Figure 21 SMLC mounting dimensions depth 52 SMLC 004a...
Страница 63: ...ServoWire Motion Logic Controller Manual Appendix B ServoWire SMM Drive 12 96 VDC System Wiring SMLC 004a 55...
Страница 65: ...ServoWire Motion Logic Controller Manual Appendix C Profibus Cable Drawing SMLC 004a 57...
Страница 66: ......