56 | USER MANUAL
OMX 103UNI
MENU
PROFI
6.
6.1.3i Setting of display projection for input 1 in mode "Teach-in"
2s
› INP. ›
› › › IN.1 ›
› › › › › › › RA.1 ›
RA.1
RA.1
Parameter
Display User
Setting
Description
Projection setting
RA.1
Setting of display projection for input 1 in
mode T.IN.
For mode SP.1 > T.IN.
Min value
MI.1
-99
…
999
Setting of display projection that corresponds
to the minimum level of input signal
• Range: -99…999
•
DEF
0
→
→
Max value
MA.1
-99
…
999
Setting of display projection that corresponds
to the maximum level of input signal
• Range: -99…999
•
DEF
100
→
→
Measurement of
Min signal
T.L.1
Connect input signal and set it to its minimum
level. In case of a moving sensor move it to its
low end position
• When the display value is stable, confirm
by
YES
→
→
Measurement of
Max signal
T.H.1
Connect input signal and set it to its maximum
level. In case of a moving sensor move it to its
high end position
• When the display value is stable, confirm
by
YES
→
→
Fixed Tare
P.T.1
-99
…
999
This setting is used when the beginning of the
range needs to be off-set by a known value
• In setting (
P.T.1
≠ 0) the symbol
INPUT
on
the display is off
• Range: -99…999
•
DEF
0
→
→
MI.1
MA.1
0
20
mA
Display
P.T.1
T.L.1
T.H.1