78 | USER MANUAL
OMX 103UNI
MENU
PROFI
6.
6.3.3a Selection of input for analogue output 1
2s
› › › OUT. ›
› › › A. O. ›
› A. 1 ›
› I.A.1 ›
I.A.1
Parameter
Display User Description
Input selection
I.A.1..
Selecting the source of data from which analogue output 1
will be calculated
Off
NO.
Analogue ouput is disabled
Channel A
C. A
Analogue ouput is based on
Channel A
DEF
Channel A with
filter
F. A
Analogue ouput is based on
Channel A
after being processed
by digital filter
Channel B
C. B
Analogue ouput is based on
Channel B
Channel B with
filter
F. B
Analogue ouput is based on
Channel B
after being processed
by digital filter
Math function
M.FN.
Analogue ouput is based on Math function
Value Min.
MIN.
Analogue ouput is based on
Value Min
Value Max.
MAX.
Analogue ouput is based on
Value Max.
→
→
I.A.1
6.3.3b Selection of analogue output 1 type
2s
› › › OUT. ›
› › › A. O. ›
› A. 1 ›
› › T.A.1 ›
T.A.1
Parameter
Display User Description
Selection of type
T.A.1..
Selection of analogue output 1
0…20 mA
I.20
4…20 mA
with indication
E.4T
Indication of a broken current loop and an error message (3 mA)
DEF
4…20 mA
with indication
4 T
Indication of a broken current loop (3 mA)
4…20 mA
with indication
E. 4
Error message (3 mA)
4…20 mA
I. 4
0…5 mA
I. 5
0…2 V
u 2
0…5 V
u 5
0…10 V
u10
±10 V
-10
→
→
T.A.1