USER MANUAL
OMX 103UNI
| 5
2.
DEVICE DESCRIPTION
MATHEMATIC FUNCTIONS
Min/Max. vale:
preserves min./max. values reached during a measurement
Tare:
is used to reset the display to zero even when the input signal does not correspond to zero
Peak value:
display projects only max. or min. value
Math operations:
polynomial, 1/x, logarithmic, exponential, power, root, sin x
and mathematic operations between inputs - sum, multiple and ratio
EXTERNAL CONTROLS
Lock :
front panel keys are blocked
Hold :
freezing the display/instrument
Tare :
applying tare/resetting tare
Resetting Min/Max : resetting of Min/Max value
■
Controls
Device is controlled by two keys located on the front panel or by OM Link SW. Settings can be realised in three
levels.
LIGHT
Simplified menu
- contains only the most essential menu items that are necessary for setting up the device.
It can be password protected.
PROFI
Complete menu
- contains all menu items and it can be password protected
USER
User define menu
- some menu item (LIGHT/PROFI) can be included into this menu. Access rights to each menu
may be assigned (to view only, or to edit)
- no password access
All configuralbe parameters are stored in EEPROM memory (remain stored even after power off).
All settings may be realised via PC' USB interface using our free to download SW called
OM Link.
OM Link „Basic“ provides for connection of 1 ORBIT MERRET device to 1 PC. OM Link also makes it possible
for the measured values to be visualised and archived in the PC. „OM Link Standard“ does exactly the sam
without the number of OM devices being limited.
■
Options
Comparators
(in the form of relays or open collectors), are designed for monitoring one to six limit values. The
user can select the limit mode: LIMIT / DOSE / FROM-TO. Limits have adjustable hysteresis in the full range
of the displayed value and an optional switch-on delay in the range of 0… 99.9 s. Reaching the set limits is
signalled by LEDs and at the same time by actuating the relevant relay.
Data outputs
Due to their speed and accuracy, data outputs are suitable for transferring measured data to
other displays, or directly to control systems. We offer isolated RS 232 and RS 485 data outputs with ASCII,
DIN MessBus and MODBUS RTU protocol, Profibus DP communication card or Ethernet.