72 | USER MANUAL
OMX 103UNI
MENU
PROFI
6.
6.3
Setting - OUTPUTS
6.3.1a Selecting the parameter limit 1 responds to
2s
› › › OUT. ›
› LIM. ›
› L. 1 ›
› INP. ›
INP.
Parameter
Display User Description
Parameter selection
INP..
Selection of data source for limit evaluation
Inactive
NO.
Limit evaluation is disabled
Channel A
C. A
Channel A is evaluated
Channel A with
filter applied
F. A
Channel A after being processed by a digital filter is evaluated
Channel B
C. B
Channel B is evaluated
DEF
Channel B with
filter applied
F. B
Channel B after being processed by a digital filter is evaluated
Math function
M.FN.
Result of the math function is evaluated
Value Min.
MIN.
Value Min. is evaluated
Value Max.
MAX.
Value Max. is evaluated
Error
ERR.
Presence of an error message is evaluated. Output is active
when there is an active error message
→
→
INP.
i
Limits 2…6
setting is the same as this Limit 1 setting
CHA.
SER.
OUT.
LIM.
A. O.
DAT.
DIS.
INP.
+
Output signal parameters are set in this
section of the menu
LIM.
Limits
DAT.
Data
A. O.
Analogue output
DIS.
Display backlight
Содержание OMX 103UNI
Страница 13: ...USER MANUAL OMX 103UNI 13 3 DEVICE CONNECTION ...
Страница 45: ...USER MANUAL OMX 103UNI 45 6 MENU PROFI ...
Страница 71: ...USER MANUAL OMX 103UNI 71 6 MENU PROFI ...
Страница 95: ......